The DlnSpiMasterGetDelayAfterSS() function retrieves the current setting for minimum delay between assertion of an SS line and the first data frame.
DlnSpiMasterGetDelayAfterSS()
DLN_RESULT DlnSpiMasterGetDelayAfterSS( HDLN handle, uint8_t port, uint32_t* delayAfterSS );
A handle to the DLN-series adapter.
A number of the SPI master port.
A pointer to an unsigned 32-bit integer that receives the current delay value in nanoseconds.
The function successfully retrieved the delay after slave selection.
The port number is not valid. Use the DlnSpiMasterGetPortCount() [1] function to find the maximum possible port number.
The DlnSpiMasterGetDelayAfterSS() function is defined in the dln_spi_master.h file.
dln_spi_master.h
Links:[1] http://dlnware.com/dll/DlnSpiMasterGetPortCount